TREMproof 201/60 – EN

Fluid-Applied, Elastomeric Coal-Tar Free Waterproofing Single Component

DESCRIPTION

TREMproof 201/60 is a high solids, VOC-compliant, bitumen modified polyurethane waterproofing membrane. It is a one-part,moisture curing elastomer available in two viscosities; Self-Leveling (SL) and Roller (R) that are suitable for applications to horizontal and vertical surfaces at 1.5mm WFT (wet film thickness).

Tremco Anti-Root Additive is available for use with TREMproof 201/60 as an optional feature to prohibit growing roots from affecting the overall performance of the waterproofing membrane.

BASIC USES

TREMproof 201/60 is suited for waterproofing in plaza decks, roof terraces, pedestrian concourses,podiums, toilets, kitchens, parking garages, planter boxes, backfilled walls, basement walls and split slabs, primarily on concrete and masonry.

FEATURES & BENEFITS

  • 1.5 mm can be applied in one coat High elongation and elastomeric properties lead to excellent crack-bridging ability
  • No primer required on clean dry concrete
  • When used with TREMproof Anti-Root Additive will inhibit root penetration through the cured membrane

PACKAGING

18.9L Pails

COLOURS

Black only

COVERAGE

TREMproof 201/60, when applied at the recommended wet film thickness of 1.5mm or 60 mils, will cover 0.67 m2 per litre (1.5 litres/ m2).
Coverage will vary with surface condition.

INSTALLATION

Even though TREMproof 201/60 is a single component product it still requires some mixing to make sure that any liquid separation that
may have occurred during shipping or storage is eliminated. Before use, mix the TREMproof 201/60 using a slow speed, high torque drill equipped with a jiffy type mixing paddle for 2-3 minutes. Take care to keep the paddle submersed in the liquid during mixing. Raising the paddle in and out of the liquid can introduce air into the coating which can lead to pinholes in the cured coating.

Refer to the appropriate method statement for the system being installed for the required application techniques, application rates, etc. The techniques involved may require modification to adjust to the jobsite conditions. Consult your Tremco Sales Representative or Tremco Asia Technical Service for site conditions requirements.

LIMITATIONS

Not for use in submerged or gas vapour conditions.

Do not apply to damp or contaminated surfaces.

Not to be used as an exposed or wearing surface.

Not approved for direct contact with asphalt-based products.

APPLICABLE STANDARDS

Conforms to ASTM c 836